NetApp FAS6210 specs
We are currently working on upgrading our specs, but here are some short details.
Maximum Raw capacity - 2400TB
Maximum disk drives - 1200
Controller form factor - Single enclosure HA; 2 controllers in singe 6U Chassis
Memory - 48GB
Flash Cache (maximum) - 3TB
PCIe Expansion slots - 8
Onboard I/O: 10GbE - 8
Onboard I/O: 8Gb FC - 8-16
Onboard I/O: 6Gb SAS - 0-8
Storage Networking supported - FC; FCoE; IP SAN (iSCSI); NFS; CIFS; HTTP; FTP
OS Version - Data ONTAP 8
High-Availability features - Alternate Control Path (ACP); Ethernet-based service processor and Data ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies, and optics
Supported Configurations:
Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA320
Disk Shelves Supported:
DS2246 (2U; 24 drives, 2.5” SAS SFF 10K RPM 450GB/600GB)
DS4243 (4U; 24 drives, 3.5” SATA 7.2K RPM 1TB/2TB; 3.5" SAS 15k RPM, 450GB/600GB; 3.5” SSD 100GB)
DS14mk2 and DS14mk4 (3U; 14 drives, 3.5” FC 450GB/600GB, 3.5” SATA 1TB/2TB)
Maximum RAID Group Sizes:
RAID 6 (RAID-DP)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 20 (18 data disks plus 2 parity disks)
RAID 4
FC: 14 (13 data disks plus 1 parity disk),
SATA: 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)
Operating Systems Supported - Windows 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux, Sun Solaris, AIX, HP-UX, Mac OS, VMware, ESX
Max. Number of LUNs - 4,096
Number of Supported SAN Hosts - Up to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair
FlexVol Volumes - Up to 500 per controller
Snapshot Copies - Up to 127,000
Maximum Volume/Aggregate Size - 70TB
Maximum port count includes integrated ports and PCIe expansion slots
FC Target Ports (8Gb/4Gb) (max) - 32/48
FCoE Target Ports, UTA (max.) - 32
10GbE Ports (max.) - 24
GbE Ports (max.) - 36
6Gb SAS Ports (max.) - 40
FC Initiator Ports (max.) - 48
Maximum Adapters:
Dual 10GbE (optical or copper) - 8
Quad GbE (copper) - 8
Dual 10GbE FCoE SAN Unified Target Adapter (optical or copper) - 8
8Gb FC Target - 8
Dual 8Gb VI for SnapMirror over Fibre Channel (SMoFC) - 6
Flash Cache Performance Acceleration Module (PAM II) - 6
Quad 6Gb SAS Storage HBA - 8
Quad 4Gb FC Storage/Tape HBA (fiber) - 8/8
Dual SCSI Tape HBA - 8
Thermal Rating - 2594 BTU (typical); 3174 BTU (worst case)
Weight - 128 lb
Height -10.2" (26cm), fits into 6U space
Width - 19" IEC rack-compliant (17.6", 44.7cm)
Depth - 24.3 (28.9 with cable management)
Operating Temperature, Altitude, and Relative Humidity - 10° C to 40° C (50° F to 104° F); at <= 3,000 m (at <= 10,000' feet) elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature)
Nonoperating Temperature and Relative Humidity - -40° C to 65° C (-40° F to 149° F); 5% to 95% relative humidity, noncondensing, in original container
Operating Acoustic Noise - ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Compliance - RoHS-compliant
Safety/Emissions/Immunity - Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI
Maximum disk drives - 1200
Controller form factor - Single enclosure HA; 2 controllers in singe 6U Chassis
Memory - 48GB
Flash Cache (maximum) - 3TB
PCIe Expansion slots - 8
Onboard I/O: 10GbE - 8
Onboard I/O: 8Gb FC - 8-16
Onboard I/O: 6Gb SAS - 0-8
Storage Networking supported - FC; FCoE; IP SAN (iSCSI); NFS; CIFS; HTTP; FTP
OS Version - Data ONTAP 8
High-Availability features - Alternate Control Path (ACP); Ethernet-based service processor and Data ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies, and optics
Supported Configurations:
Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA320
Disk Shelves Supported:
DS2246 (2U; 24 drives, 2.5” SAS SFF 10K RPM 450GB/600GB)
DS4243 (4U; 24 drives, 3.5” SATA 7.2K RPM 1TB/2TB; 3.5" SAS 15k RPM, 450GB/600GB; 3.5” SSD 100GB)
DS14mk2 and DS14mk4 (3U; 14 drives, 3.5” FC 450GB/600GB, 3.5” SATA 1TB/2TB)
Maximum RAID Group Sizes:
RAID 6 (RAID-DP)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 20 (18 data disks plus 2 parity disks)
RAID 4
FC: 14 (13 data disks plus 1 parity disk),
SATA: 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)
Operating Systems Supported - Windows 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux, Sun Solaris, AIX, HP-UX, Mac OS, VMware, ESX
Max. Number of LUNs - 4,096
Number of Supported SAN Hosts - Up to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair
FlexVol Volumes - Up to 500 per controller
Snapshot Copies - Up to 127,000
Maximum Volume/Aggregate Size - 70TB
Maximum port count includes integrated ports and PCIe expansion slots
FC Target Ports (8Gb/4Gb) (max) - 32/48
FCoE Target Ports, UTA (max.) - 32
10GbE Ports (max.) - 24
GbE Ports (max.) - 36
6Gb SAS Ports (max.) - 40
FC Initiator Ports (max.) - 48
Maximum Adapters:
Dual 10GbE (optical or copper) - 8
Quad GbE (copper) - 8
Dual 10GbE FCoE SAN Unified Target Adapter (optical or copper) - 8
8Gb FC Target - 8
Dual 8Gb VI for SnapMirror over Fibre Channel (SMoFC) - 6
Flash Cache Performance Acceleration Module (PAM II) - 6
Quad 6Gb SAS Storage HBA - 8
Quad 4Gb FC Storage/Tape HBA (fiber) - 8/8
Dual SCSI Tape HBA - 8
Thermal Rating - 2594 BTU (typical); 3174 BTU (worst case)
Weight - 128 lb
Height -10.2" (26cm), fits into 6U space
Width - 19" IEC rack-compliant (17.6", 44.7cm)
Depth - 24.3 (28.9 with cable management)
Operating Temperature, Altitude, and Relative Humidity - 10° C to 40° C (50° F to 104° F); at <= 3,000 m (at <= 10,000' feet) elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature)
Nonoperating Temperature and Relative Humidity - -40° C to 65° C (-40° F to 149° F); 5% to 95% relative humidity, noncondensing, in original container
Operating Acoustic Noise - ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Compliance - RoHS-compliant
Safety/Emissions/Immunity - Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI
also know as: NetApp FAS6200 Series
If you are interested in using our specs commercially, check out our Network Attached Storage specs database licensing page.
Filed in: NetApp Network Attached Storage
Description: Harness the power of our FAS6200 series’ scalability, availability, and flexibility for your most demanding application needs and rely on it for your ever-changing virtualized and cloud environments.