We are currently working on upgrading our specs, but here are some short details.
Maximum Raw Capacity - 2,880 TB
Maximum Disk Drives - 1,440
Controller Form Factor - Dual enclosures HA; 2 controllers in two 6U chassis, total of 12U
Memory - 96GB
Flash Cache - 6TB
PCIe Expansion - 24
Onboard I/O 10GbE - 8
Onboard I/O 8GbE - 8-32
Onboard I/O 6GbE - 0-24
Storage networking supported - FC; FCoE; IP SAN (iSCSI); NFS; CIFS; HTTP; FTP
OS version - Data ONTAP 8
High Availability features - Alternate Control Path (ACP);
Ethernet-based service processor and Data ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies, and optics
Supported configurations:
Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA320
Disk shelves Supported:
DS2246 (2U; 24 drives, 2.5” SAS SFF 10K RPM 450GB/600GB)
DS4243 (4U; 24 drives, 3.5” SATA 7.2K RPM 1TB/2TB; 3.5" SAS 15k RPM, 450GB/600GB; 3.5” SSD 100GB)
DS14mk2 and DS14mk4 (3U; 14 drives, 3.5” FC 450GB/600GB, 3.5” SATA 1TB/2TB)
Maximum RAID Group Sizes:
RAID 6 (RAID-DP)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 20 (18 data disks plus 2 parity disks)
RAID 4
FC: 14 (13 data disks plus 1 parity disk),
SATA: 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)
Operating Systems Supported - Windows 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux, Sun Solaris, AIX, HP-UX, Mac OS, VMware, ESX
Max. Number of LUNs - 4,096
Number of Supported SAN Hosts:
Up to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair
FlexVol Volumes - Up to 500 per controller
Maximum volume size - 100 TB
FC Target Ports - 48/48
FCoE Target Ports, UTA (max) - 40
GbE Ports (max.) - 100
6 Gb SAS Ports (max.) - 128
Maximum adapters:
Dual 10GbE (optical or copper) - 16
Quad GbE (copper) - 24
Dyak 10GbE FCoE SAN Unified Target Adapter (optical or copper) - 24
8Gb FC Target - 24
Dual 8Gb VI for SnapMirror over Fibre Channel (SMoFC) - 8
Flash Cache Performance Acceleration Modul (PAM II) - 12
Quad 6Gb SAS Storage HBA - 12
Quad 4Gb FC Storage/Tape HBA (fiber) - 24/16
Dual SCSI tape HBA - 16
Thermal Rating - 4268 BTU (typical); 6280 BTU (worst case)
Weight - 246 lb
Height - 20.4" (52 cm), fits into 12U space
Width - 19" IEC rack-compliant (17.6", 44.7 cm)
Depth - 24.3" (28.9" with cable management)
Operating Temperature, Altitude, and Relative Humidity - 10° C to 40° C (50° F to 104° F); at <= 3,000 m (at <= 10,000' feet) elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature)
Nonoperating temperature and relative humidity - -40° C to 65° C (-40° F to 149° F); 5% to 95% relative humidity, noncondensing, in original container
Operating Acoustic Noise - ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Rack Space - 42U
Dimensions (height/width/depth) - 78.75" (200 cm)/23.6" (60 cm)/44.3" (112.5 cm)
Minimum Cabinet Clearances for Airflow - 10" (25.4 cm) front and 12” (30.5 cm) rear
Minimum Cabinet Clearances for Service - 30” (76.3 cm) front and rear, 12” top
AC Power - 200 to 240VAC
Current - 30A Single Phase or 3-Phase
Weight (empty) - 307 lbs (138 kg)
Features - Split rear door with cable egress opening, reversible front door (left or right handed),
Maximum Disk Drives - 1,440
Controller Form Factor - Dual enclosures HA; 2 controllers in two 6U chassis, total of 12U
Memory - 96GB
Flash Cache - 6TB
PCIe Expansion - 24
Onboard I/O 10GbE - 8
Onboard I/O 8GbE - 8-32
Onboard I/O 6GbE - 0-24
Storage networking supported - FC; FCoE; IP SAN (iSCSI); NFS; CIFS; HTTP; FTP
OS version - Data ONTAP 8
High Availability features - Alternate Control Path (ACP);
Ethernet-based service processor and Data ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies, and optics
Supported configurations:
Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA320
Disk shelves Supported:
DS2246 (2U; 24 drives, 2.5” SAS SFF 10K RPM 450GB/600GB)
DS4243 (4U; 24 drives, 3.5” SATA 7.2K RPM 1TB/2TB; 3.5" SAS 15k RPM, 450GB/600GB; 3.5” SSD 100GB)
DS14mk2 and DS14mk4 (3U; 14 drives, 3.5” FC 450GB/600GB, 3.5” SATA 1TB/2TB)
Maximum RAID Group Sizes:
RAID 6 (RAID-DP)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 20 (18 data disks plus 2 parity disks)
RAID 4
FC: 14 (13 data disks plus 1 parity disk),
SATA: 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)
Operating Systems Supported - Windows 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux, Sun Solaris, AIX, HP-UX, Mac OS, VMware, ESX
Max. Number of LUNs - 4,096
Number of Supported SAN Hosts:
Up to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair
FlexVol Volumes - Up to 500 per controller
Maximum volume size - 100 TB
FC Target Ports - 48/48
FCoE Target Ports, UTA (max) - 40
GbE Ports (max.) - 100
6 Gb SAS Ports (max.) - 128
Maximum adapters:
Dual 10GbE (optical or copper) - 16
Quad GbE (copper) - 24
Dyak 10GbE FCoE SAN Unified Target Adapter (optical or copper) - 24
8Gb FC Target - 24
Dual 8Gb VI for SnapMirror over Fibre Channel (SMoFC) - 8
Flash Cache Performance Acceleration Modul (PAM II) - 12
Quad 6Gb SAS Storage HBA - 12
Quad 4Gb FC Storage/Tape HBA (fiber) - 24/16
Dual SCSI tape HBA - 16
Thermal Rating - 4268 BTU (typical); 6280 BTU (worst case)
Weight - 246 lb
Height - 20.4" (52 cm), fits into 12U space
Width - 19" IEC rack-compliant (17.6", 44.7 cm)
Depth - 24.3" (28.9" with cable management)
Operating Temperature, Altitude, and Relative Humidity - 10° C to 40° C (50° F to 104° F); at <= 3,000 m (at <= 10,000' feet) elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature)
Nonoperating temperature and relative humidity - -40° C to 65° C (-40° F to 149° F); 5% to 95% relative humidity, noncondensing, in original container
Operating Acoustic Noise - ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Rack Space - 42U
Dimensions (height/width/depth) - 78.75" (200 cm)/23.6" (60 cm)/44.3" (112.5 cm)
Minimum Cabinet Clearances for Airflow - 10" (25.4 cm) front and 12” (30.5 cm) rear
Minimum Cabinet Clearances for Service - 30” (76.3 cm) front and rear, 12” top
AC Power - 200 to 240VAC
Current - 30A Single Phase or 3-Phase
Weight (empty) - 307 lbs (138 kg)
Features - Split rear door with cable egress opening, reversible front door (left or right handed),
also know as: NetApp FAS6200 Series
If you are interested in using our specs commercially, check out our Network Attached Storage specs database licensing page.
Filed in: NetApp Network Attached Storage
Description: Harness the power of our FAS6200 series’ scalability, availability, and flexibility for your most demanding application needs and rely on it for your ever-changing virtualized and cloud environments.